Other Considerations.
他の検討事項
Effects on reproductive organs were also considered in the
research program. Due to the shallow penetration depth of millimeter waves, there is no
damage to reproductive organs. As part of the verification testing, a sperm
motility/morphology study was conducted and verified no effects. Likewise, pacemakers,
metal implants, artificial hips, etc. are unaffected by millimeter waves.
4 Chalfin S, D’Andrea JA, Comeau PD, Belt ME and Hatcher DJ (2002). Millimeter wave absorption in the
nonhuman primate eye at 35GHz and 94GHz. Health Physics, 83, 83-90.
5 Foster KR, D’Andrea JA, Chalfin, S, and Hatcher, DJ (2003). Thermal Modeling of Millimeter Wave
Damage to the primate cornea at 35GHz and 94 GHz. Health Physics, 84(6): 764-769.
6 Mason, PA, Walters, TJ, DiGiovanni, J, Beason, CW, Jauchem, JR, Dick, EJ, Jr., Mahajan, K, Dusch, SJ,
Shields, BA, Merritt, JH, Murphy, MR, and Ryan, KL (2001). Lack of Effect of 94.0 GHz Radio
Frequency Radiation Exposure in an Animal Model of Skin Carcinogenesis. Carcinogenesis, 22:1701-
1708, 2001.
生殖噐への用も又、調査プログラムの中で検討された。
20:47 2017/05/20土
-